Accurate
With its self-monitoring algorithms and an internal spectral
line source, the WaveMaster auto-calibrates the internal
spectrometer to maintain accuracy.
Easy Set-Up
Feedback from the WaveMaster is straightforward. Once the
signal is applied to the probe, the unit begins sampling to
simplify set-up. In CW mode, the WaveMaster will auto-range
to adjust the sensor integration time to match the incoming
signal. This allows the quickest set-up and greatest versatility.
Selected Display Units
The wavelength readings can be displayed in nanometers
in “air” at standard temperature and pressure (STP), or
shown as a calculated conversion from STP to nanometers
in a “vacuum”, or displayed as wave numbers (cm
-1
), or as
frequency (GHz).
The WaveMaster measures the wavelength of both CW and
pulsed lasers of any repetition rate. The wavelength can be
displayed in GHz, wave numbers, or nanometers, with vacuum
and air readings available. The WaveMaster will read the
peak wavelength of sources as wide as 2 nm from 380 nm to
1095 nm. Bandwidths wider than 2 nm can be accommodated
at the longer wavelengths.
The WaveMaster is easy to use. Just turn on the readout
and get the beam within 10 degrees of normal incidence
to the sampling probe. The probe has a 2-meter beroptic
cable and takes up a minimum of beam path space. Most
intensity variances are automatically accommodated, but for
the strongest and weakest signals a front panel attenuator
adjustment and intensity readout quickly produce accurate
readings. No special triggering modes or setups are required
for pulse capture.
Laser
Cross-
Reference
Index
POWER
& ENERGY
Power
Sensors
Energy
Sensors
Custom
& OEM
BEAM
DIAGNOSTICS
CALIBRATION
& SERVICE
INDICES
Product
Name
Index
Power
& Energy
Meters
Laser Wavelength Meter
WaveMaster
User-Friendly
The WaveMaster is easy to read with front panel adjustments
of contrast and back-lighting for the extra-large display.
Parameters that have been set-up are clearly displayed, in
addition to signal intensity and pulse-retrieved indicators.
Conguration settings are maintained in memory and
retrieved on start-up for convenience. Communication with
the WaveMaster is also easy with a built-in RS-232 port.
Sophisticated algorithms that monitor the WaveMaster’s
response maintain calibration. Periodically, and upon
indication from the algorithms, the WaveMaster is referenced
to the fundamental lines of an internal NE source.
Pulse or CW Operation
The operational mode can be changed from CW, to CW with
averaging, to pulse. In CW mode the display is updated at
3 Hz. In CW with averaging, the display is updated at 3 Hz
with an average of the last 10 readings taken at 3 Hz. For pulse
mode, when a valid pulse is received the display will show
the wavelength reading of the pulse for 15 seconds, or until
another valid pulse is received.
No Warm-Up Time
When the WaveMaster is rst powered on, it will perform a
self-test cycle and then enter the auto-calibration mode. After
10 seconds, the AUTOCAL message is cleared from the display
and the WaveMaster is ready to make measurements.